Welcome to Kena Environmental Technology Co., LTD

Do you know what the consequences of high -temperature smokexhaust fan arnoinstalled in accordancwith regulio?

Views :
Update time : 2024-06-30

High -temperature smoke is used for all walks of life, and playing an important role in the high -temperature smoke discharge system. Fire -fighting incidents are often sudden, without warning. Once the fire occurs, the fire will spread sharply, so fire smoke will start.To ignore the role that cannot be ignored.
The irregular installation of high -temperature smoke fan will affect the fan smoke discharge function. In order to prevent these unnecessary failures in the later period, we need to clarify the consequences of improper installation, so that they can pay attention to the attention of their staff and users.The following editors will introduce the consequences of irregular installation of high -temperature smoke exhaust fan:
1. Insufficient foundation of foundation: If the foundation of the fan is not strong enough, it may cause vibration during operation, affect the normal operation of the fan, and may even cause a fan failure or damage.
2. Improper installation of vibration reduction device: When installing the vibration reduction device, if the shock absorption treatment is not performed in accordance with regulations, it may cause excessive vibration and noise during the operation of the fan, which will affect the surrounding environment and human health.
3. Incorrect direction of the rotation of the leaf: If the rotation direction of the impeller is incorrect, it may cause the efficiency of the fan to be reduced or even working properly.
4. The gap between the impeller and the shell is uneven: If the gap between the impeller and the shell is uneven, it may cause vibration and noise during the operation of the fan, and may cause a fan failure or damage in severe cases.
5. Safety wiring is irregular: If the safety wiring is irregular, it may produce excessive heat or electric spark during the operation of the fan, causing safety accidents such as fire or explosion.
6. No debugging and trial operation after installation: If no debugging and trial operation is not performed after high -temperature smoke exhaust fan installation, various problems may cause the fan at the formal operation.
Therefore, in order to ensure the normal operation and safety of high temperature smoke exhaust fan, correct installation, debugging and trial operation must be performed in accordance with regulations.
The above is the consequences that the high -temperature smoke exhaust fan is not installed as required. I hope it can be helpful to you. If you want to know more information, please pay more attention to us ——

Related News
Read More >>
Pipe connection method of air Pipe connection method of air
06 .18.2024
Air suspension fans are efficient, environmentally friendly ventilation equipmen
Installation and debugging of Installation and debugging of
06 .18.2024
Before installation: Before installation, first prepare the materials and tools
Advantages and adjustment meth Advantages and adjustment meth
06 .18.2024
A centrifugal fan is a mechanical device that relies on input mechanical energy
How to debug a centrifugal cur How to debug a centrifugal cur
06 .30.2024
The debugging of the centrifugal curtain machine mainly includes the following s

Leave Your Message