The debugging of the centrifugal curtain machine mainly includes the following steps:
1. Check the installation: First, to ensure that the installation location and direction of the centrifugal curtain machine are correct, and the door or channel cannot be covered. At the same time, it is necessary to ensure that the screws, pipeline interfaces, and power cord interfaces are firm and reliable.
2. Check the power supply: Check whether the working voltage of the power supply provided to the fan meets the requirements, whether the power supply is missing or the same as the phase, and whether the capacity of the distribution disk component meets the requirements.
3. Trial operation: During the trial operation, the number of tasting people should be more than two. One person controls the power supply, and one person observes the fan operation of the fan.During the trial operation, you should first check whether the rotation direction is correct.After the centrifugal fan starts to run, check whether the running current of each phase is balanced and whether the current exceeds the rated current.After running for 5 minutes, stop checking the fan of the fan. Confirm that there is no abnormality and connect the power to continue running.
4. Pay attention to the launch method: The centrifugal curtain machine allows to start under full-voltage or antihypertensive electric conditions, but please note that the current at full pressure start is about 5-7 times the rated current.Setting up torque is proportional to the square of the voltage. When the power grid capacity is insufficient, please use the boost to start.
5. Adjust performance: According to actual needs, adjust the performance parameters of the weather curtain, such as wind speed and corner.At the same time, it is necessary to pay attention to adjusting temperature and humidity so that it meets the differences and humidity of indoor and outdoor.
6. Failure: If you find noise, poor airflow or stopping, etc., the failure needs to be eliminated in time.You can check whether the power cord and the interface are loose, whether the pipeline is blocked, and whether the fan fails, and is repaired and replaced.
7. Safety precautions: During the debugging process, pay attention to safe use to avoid electric shock danger.At the same time, the air curtain machine has a certain suction when it is running, and it should be kept a certain distance to avoid the leaves from hurting people.In addition, long -term direct sunlight will affect the performance and service life of the screen, and avoid direct sunlight during installation.
After completing the above steps, the centrifugal curtain machine should be able to run normally and achieve the expected results.If necessary, you can seek the help of professionals.
The above is the introduction of how to debug the centrifugal curtain machine

Related News
Read More >>
Pipe connection method of air Pipe connection method of air
06 .18.2024
Air suspension fans are efficient, environmentally friendly ventilation equipmen
Installation and debugging of Installation and debugging of
06 .18.2024
Before installation: Before installation, first prepare the materials and tools
Advantages and adjustment meth Advantages and adjustment meth
06 .18.2024
A centrifugal fan is a mechanical device that relies on input mechanical energy
How to debug a centrifugal cur How to debug a centrifugal cur
06 .30.2024
The debugging of the centrifugal curtain machine mainly includes the following s

Leave Your Message