The working principle of the straightforward constant temperature constant humidity purification air conditioner can be divided into the following main steps:
Compressor work:
The air -conditioning unit is equipped with a compressor, which is responsible for inhaling low -temperature and low -voltage refrigerants.By compressed, increase the temperature and pressure of the refrigerant, and then discharge high -temperature and high -pressure refrigerants.
Cooling device cooling:
High -temperature and high -pressure refrigerant enters the condenser.Under the condensation of external air, the temperature of the refrigerant is reduced to transform it from gaseous to liquid.
Expansion valve adjustment:
After the refrigerant is condenser, enter the expansion valve.The expansion valve enters the evaporator by regulating the flow and pressure of the refrigerant.
Steamor absorbing heat:
Refrder absorbs the heat of the air in the evaporator, leading to a decrease in the temperature of the air, thereby achieving the cooling effect of the air.The cold wind generated by the evaporator passes through the loop of the fan, sending the cold wind into the indoor environment that needs to be refrigerated, and at the same time discharge the indoor hot air.
Constant temperature and humidity control:
The direct -swollen constant temperature and humidity purification air conditioner not only has the refrigeration function, but also can directly exchange thermal exchange with the air through the refrigerant to regulate the temperature and humidity of the air.
The indoor machine is equipped with a temperature and humidity sensor and controller, which can monitor and control the indoor temperature and humidity in real time to ensure that the indoor environment is in a constant temperature and humidity state.
Air purification:
The direct -swollen constant temperature and humidity purification air conditioner also has functions such as dust removal, which can clean the indoor air.The standard air conditioner uses medium -efficiency filtering device to clean the indoor air. It can also choose sub -efficient air filters according to the customers needs.
High -efficiency control:
The control system adopts the UAC micro -computer control system, and the operation of the unit is controlled by the ground and efficiently.Provide 36 alarms that can be performed by networking through communication interfaces to ensure the safe and stable operation of the machine.
The above is the working principle of a direct -swollen constant temperature constant humidity purification air conditioner