New Backwind Mixed Section
1. The position of the new return air outlet can be set on the end, top, or left and right sides according to the design requirements.On the new return air outlet, the installation valve can be installed. The execution agency has three types: manual, electric and pneumatic, which is selected by users.
2. There are two types of filtering sections: early and medium -efficiency filtration, with diamond -shaped bag type, four -peak bag type, and can also be equipped with automatic rolling type. The filter material has no woven fabric with high -quality polyester wheels.Institution, cover and alarm device.
New rowing section
(Also known as Pingding Division Wind Mixed Section) There is a wind return valve in the box in this section. There is a row of air outlets and new air outlets on each top of the boxes before and after the valve.The air -conditioning machine discharge part of the wind, so that the fresh air and a return air are mixed according to the required proportion; when the DC system is used in the transition season, the air return valve should be turned off to open the exhaust valve and the new wind valve.
Energy recovery section
For double wind turbine systems for cross -separation and exhaust energy recycling.There is a wind return valve in the box in this section, and the top is an energy recyler. It is an indirect cooling (heating) fresh air that uses the cold (heat) of the exhaust.About 60%of energy.At the same time, the exhaust and fresh air do not directly contact, and it is particularly suitable for the energy recovery of the DC air conditioning system of the harmful gas indoor.When using the DC system, it should be closed once the air return valve should be closed. There should be a separate air exhaust system in the venue venue, and this section should not be used.
Middle section (maintenance section)
The connection and internal maintenance and lighting of the crew from the transition section.Before the filtering section, the intermediate section must be set up before and after the surface of the surface, heating section, and the disappearance section.
Secondary background
Connect the middle section of the second air supply pipe, and the top can be provided with a regulatory valve, equipped with a manual, electric or pneumatic regulatory mechanism, which is selected by the user.
The cooler adopts the structure of aluminum foil with a copper tube of 4, six, and eight tubes. The aluminum foil is the form of double -edged ripple edges.The form of mechanical rising tube guarantees the contact performance of the heat exchanger. The thermal exchanger is divided into two types: fixed and rotating type. Users can choose one as needed. The heat media uses steam or hot water.
The above is the introduction of the functional segment of the combined air conditioning unit