Welcome to Kena Environmental Technology Co., LTD

What are the common questions in thusof smokand firpventi valves during use

Views :
Update time : 2024-06-30

In engineering construction equipment, the fire valve is an indispensable fire protection facility. It can effectively prevent the spread of fires and play a role in closing environmental safety.In order to reduce danger and prevent hidden safety hazards, today I will introduce to you what common questions will be in the use of smoke and fire prevention valves, please refer to it!
1. The fire control room and the return air pipeline did not have a smoke exhaust fire valve at the wall.The purpose of setting up a fire prevention valve in the fire control room is to ensure the fire safety of the fire control room. However, during the construction review, it was found that there were no fire valves in the emperor control room on the engineering design drawings.
2. The fire control equipment controls the dust, smoke exhaust devices, and the flashing functions.According to Article 6.3.9 of GB50116-98: After the fire alarm is recognized, it is necessary to interrupt the air-conditioning air supply of the relevant parts, turn off the electric smoke fire prevention valve, and receive its reaction signal; at the same time, Tobacco discharge valve, etc., and receive their feedback signals.
3. There is no aerodynamic fire extinguishing valve.Article 6.3.4.3 of GB50116-98 Requirements: "During the fire delay period, the fire door should be automatically closed, the air-conditioning system should not be ventilated, and the fire valve device of the relevant parts should be closed.Tobacco fire prevention valve, link with fire control equipment.
4. There is no remote control in the air supply and exhaust channel.In some buildings basement and choosing a smoke exhaust duct in the parking lot, the deeper valve in front of the air supply and exhaust machine can only be manually manually controlled at the scene.The cut -off valve before turning off the fan will directly affect the smoke discharge system.It is recommended to increase the remote control function to achieve remote control.
Although the planning of smoke and fire valve system pipeline planning, although the calculation has changed, the actual engineering operating conditions have changed, and the air volume of the system of the system must be adjusted through smoke discharge fire valve and valve., Meet the planning requirements.
The above is some of the common problems in the use of smoke and fire prevention valves. I hope it can help you. For more relevant information, please pay more attention to us -Texas Environmental Protection Technology Co., Ltd. (14705348338 Lin) is a professional production heatingThe manufacturing, sales, installation and technical services of ventilation equipment, central air -conditioning at the end of the central air -conditioning equipment and accessories, etc., is located in the North Daimen of Shandong — the vibrant Wusheng Economic Development Zone in Shandong.The companys products are complete, mainly focusing on the production of high -space warm and warm units, wall fan, (water, electric, steam) heating fan, flow -type air curtain, centrifugal air curtain, vertical side blowing air screen, ceiling air conditioner, ceiling air conditioner, ceiling air conditioner, ceiling air conditionerUnits, fresh air firing machines, shaft fans, low noise firms, fan, air outlet valve, duct, water tank, water tank, civil air defense, cooling tower, muffled static pressure box and other central air -conditioning host accessories and central air -conditioning end accessories and other series of productsEssence
We always adhere to: positive, satisfactory, enthusiastic ideas, and provide high -quality products and services for new and old customers.We are the central air -conditioning integration manufacturer you can trust!
Border wall explosion -proof shaft flow fan rainfall and insect -proof edge wall fan
Tall space ceiling air -conditioner small vibration and small use safety reliability high
Tall space ceiling air -conditioning unit work efficiency high maintenance costs are low
Tall space air -conditioning units of air circulating heat -making unit running stable wireless control
Tall space warm and warm units Low warm wind crew warehouse plant heating and refrigeration equipment
Tall space dedicated circular air and hot and cold units operate steadily, energy saving low -carbon quality high
Wall -style exhaust lane aluminum -style wall fan square wall stroke fan
The side wall of the side wall is strong, thick, material integrated molding

Related News
Read More >>
Pipe connection method of air Pipe connection method of air
06 .18.2024
Air suspension fans are efficient, environmentally friendly ventilation equipmen
Installation and debugging of Installation and debugging of
06 .18.2024
Before installation: Before installation, first prepare the materials and tools
Advantages and adjustment meth Advantages and adjustment meth
06 .18.2024
A centrifugal fan is a mechanical device that relies on input mechanical energy
How to debug a centrifugal cur How to debug a centrifugal cur
06 .30.2024
The debugging of the centrifugal curtain machine mainly includes the following s

Leave Your Message